Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Ultramid® B3Z ST - PA6-I - BASF

Material Data Center offers the following functions for Ultramid® B3Z ST:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Ultramid B datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts
High impact modified Polyamide 6 providing extremely high impact strength especially at low temperatures and in dry conditions. Ultramid® B3Z ST is used e.g. in co-extruded containers as barrier layer and to improve the mechanical properties of the container.
Processing/Physical Characteristicsdry / condUnitTest Standard
ISO Data
Melt volume-flow rate, MVR 40 / * cm³/10min ISO 1133
Temperature 275 / * °C -
Load 5 / * kg -
Molding shrinkage, parallel 1.2 / * % ISO 294-4, 2577
Molding shrinkage, normal 1.4 / * % ISO 294-4, 2577
Mechanical propertiesdry / condUnitTest Standard
ISO Data
Tensile Modulus 1550 / 410 MPa ISO 527
Yield stress 42 / 21 MPa ISO 527
Yield strain 4.5 / 18.6 % ISO 527
Nominal strain at break >50 / - % ISO 527
Charpy impact strength, +23°C N / N kJ/m² ISO 179/1eU
Charpy impact strength, -30°C N / N kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 80.8 / 120 kJ/m² ISO 179/1eA
Charpy notched impact strength, -30°C 29 / 33 kJ/m² ISO 179/1eA
Thermal propertiesdry / condUnitTest Standard
ISO Data
Melting temperature, 10°C/min 220 / * °C ISO 11357-1/-3
Temp. of deflection under load, 1.80 MPa 55 / * °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 130 / * °C ISO 75-1/-2
Coeff. of linear therm. expansion, parallel 160 / * E-6/K ISO 11359-1/-2
Burning Behav. at thickness h HB / * class IEC 60695-11-10
Thickness tested 0.8 / * mm -
Electrical propertiesdry / condUnitTest Standard
ISO Data
Comparative tracking index - / 550 - IEC 60112
Other propertiesdry / condUnitTest Standard
Water absorption 8 / * % Sim. to ISO 62
Humidity absorption 2.5 / * % Sim. to ISO 62
Density 1050 / - kg/m³ ISO 1183
Material specific propertiesdry / condUnitTest Standard
ISO Data
Viscosity number 155 / * cm³/g ISO 307, 1157, 1628
Diagrams
Stress-strain , Ultramid® B3Z ST (dry), PA6-I, BASF
Stress-strain , Ultramid® B3Z ST (cond.), PA6-I, BASF
Secant modulus-strain , Ultramid® B3Z ST (dry), PA6-I, BASF
Secant modulus-strain , Ultramid® B3Z ST (cond.), PA6-I, BASF
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Special Characteristics
High impact or impact modified
Regional Availability
Europe
Other text information
Injection molding
PREPROCESSING
Pre/Post-processing, max. allowed water content: .15 %
Pre/Post-processing, Pre-drying, Temperature: 80 °C
Pre/Post-processing, Pre-drying, Time: 4 h

PROCESSING
injection molding, Melt temperature, range: 250 - 270 °C
injection molding, Melt temperature, recommended: 260 °C
injection molding, Mold temperature, range: 40 - 60 °C
injection molding, Mold temperature, recommended: 60 °C
injection molding, Dwell time, thermoplastics: 10 min
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.